Tandberg Data DPS Expansion Module Disk Pack Specifications Page 60

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 59
54 |
Cooling fan module LED
The Cooling Fan module incorporates a Module Fault LED (amber), defined below.
OPS panel LEDs
The OPS panel displays the aggregated status of all the modules.
The following OPS panel LED states are available:
Fault LED (Amber) Status
OFF Fan OK.
ON One or more fans have failed.
OPS Panel LEDs
Other Associated
LEDs or Alarms
State Description
Power
On
(Green)
System
Fault
(Amber)
Logical
Fault
(Amber)
Box
Identify
(Blue)
ON ON ON ON Single beep, two
double beep.
Power On Self Test.
ON OFF OFF - Power On, all
functions good.
ON ON - - Power Supply Fault
LED or Cooling Fan
Module Fault LED.
Any power supply
fault, cooling fan
module fault, or
over/under
temperature
condition.
ON ON - - RAID Controller
Fault LED is On
(affected controller).
A RAID Controller
Fault.
Page view 59